Wildfire Defence & Defensible Space

The work that decides whether the house is still there

Difficulty

Intermediate

Build time

Ongoing seasonal work

Material cost

$200 – $4,000

Crew

1 – 3 people

Overview

Structure survival in a wildfire is decided mostly by two things: embers finding a way into the building, and what is burning within 30 ft of the walls. This entry covers the three defensible-space zones, ember-proofing details that matter more than clearing brush, an independent water supply for defence, and the go/no-go decision that keeps people alive.

Key figures

Zone 1
0 – 5 ft: non-combustible only
Zone 2
5 – 30 ft: lean, clean, green
Zone 3
30 – 100 ft: thinned and limbed
Vent screening
1/8 in metal mesh maximum aperture
Defence water
2,500 gal reserved, dedicated
Ember travel
Up to a mile ahead of the fire front

Read before starting

  • 01Never plan to stay and defend unless you are physically capable, properly equipped, and have a triggered decision point. Most wildfire deaths happen during late evacuation, not during defence.
  • 02Radiant heat kills before flame arrives. If you cannot shelter inside a structure, you cannot defend it.
  • 03Plan two independent evacuation routes and a written trigger for leaving. Decide in advance, not during.
  • 04Hoses, plastic tanks and above-ground pipework melt in radiant heat. Anything you rely on for defence must be metal or buried.
  • 05Mains and inverter power will fail. Any defence pump must be petrol, diesel, or on a dedicated battery.
  • 06Never work with chainsaws or brushcutters on a total fire ban day. Tools start fires.

Procedure

0/9 complete
  1. Understand how houses actually burn

    Most structures lost in wildfires are not consumed by a passing flame front. They are ignited by embers, hours before or after, landing in gutters, entering roof vents, or catching fine fuel against the wall. That reality should reorder your priorities: ember-proofing the building comes before clearing distant brush.

  2. Clear Zone 1 completely — 0 to 5 ft

    Within 5 ft of every wall: no bark mulch, no shrubs against the cladding, no firewood stack, no plastic furniture, no doormat, nothing stored under a deck. Replace organic mulch with gravel. This narrow band is the highest-value work on the entire property, and it is essentially free.

    Hazard · A firewood stack against the house wall is the single most reliable way to lose a building. Move it 30 ft away.

  3. Manage Zone 2 — 5 to 30 ft

    Lean, clean and green. Keep grass short and irrigated where you can, break up continuous vegetation into islands, remove dead material, and leave at least 10 ft between tree canopies. Remove any ladder fuel — shrubs beneath trees that let a ground fire climb into the crowns.

  4. Thin Zone 3 — 30 to 100 ft

    Thin the understorey, limb trees up 6 – 10 ft from the ground, and remove dead standing timber. You are not clear-felling; you are removing the vertical and horizontal continuity that lets fire build intensity as it approaches. Chip or burn slash promptly — a slash pile is stored fire.

  5. Ember-proof the building

    Screen every vent, weephole, soffit and subfloor opening with 1/8 in metal mesh. Fit non-combustible gutter guards. Seal gaps at the roof-wall junction and around penetrations with fire-rated sealant. Box in open eaves. Replace or upgrade any single-pane glass — glass failure lets embers straight in.

    Field tip · Crawl the whole perimeter on your hands and knees looking for any opening bigger than 1/8 in. That is exactly the survey a firefighter would do.

  6. Harden the decks and outbuildings

    Enclose the underside of decks with mesh and clear everything stored beneath. Replace flammable deck furniture cushions before fire season. Treat every outbuilding within 30 ft of the house as part of the house — a burning shed will ignite the wall next to it.

  7. Build an independent water supply

    Reserve at least 2,500 gal in a tank with metal outlet fittings, plumbed to a petrol or diesel pump with metal hose and nozzles. Solar and inverter power will not be available; plastic fittings will melt. Fit a dedicated outlet at the bottom of the tank clearly labelled for fire use so this reserve is never drawn down for irrigation.

    Hazard · A plastic tank with plastic fittings, or a hose reel of garden hose, is not a firefighting system. Radiant heat destroys them.

  8. Write the trigger and the plan

    Decide in advance and in writing: at what fire danger rating, or what distance, you leave. Include two routes out, a rendezvous point, who collects the animals, and what goes in the vehicle. Practise it once. The families who survive are the ones who decided before the day, not during it.

    Hazard · If your plan is to leave, leave early. Late evacuation through smoke on a rural road is the most lethal part of any wildfire.

  9. Prepare the go-bags and the seasonal routine

    Pack documents, medications, water, wool blankets, P2 masks, boots, torches and radio into a bag per person, staged by the door in fire season. Each week in high season: clear gutters and roof valleys, mow, check the pump starts, and confirm your defence tank is full.

Maintenance schedule

Weekly in fire seasonClear gutters, roof valleys and decks of leaf litter
Weekly in fire seasonStart the fire pump and run it for five minutes
MonthlyMow and slash grass in Zone 2; check the reserve tank is full
Before each seasonFull defensible-space audit of all three zones
AnnuallyInspect every ember screen for damage; reseal gaps; service the pump
AnnuallyReview the evacuation plan with everyone and refresh go-bags

Fault finding

Embers found inside the roof space after a nearby fire

Likely causeUnscreened or damaged vent

CorrectionInspect and re-screen every opening with 1/8 in metal mesh. Check for rodent damage annually.

Fire pump will not start when tested

Likely causeStale fuel or a flat battery

CorrectionRun it monthly, use fuel stabiliser, and keep any starter battery on a maintainer.

Reserve tank low at the start of fire season

Likely causeFire reserve used for irrigation

CorrectionFit a dedicated low-level outlet for fire use only and label it. Never plumb the reserve into the irrigation system.

Gutters full again a week after clearing

Likely causeOverhanging trees

CorrectionLimb back overhanging branches and fit non-combustible gutter guards.