Solar Well Pump & Pressure System

Pump from the bore to a pressure tap without a generator

Difficulty

Advanced

Build time

2 – 3 days

Material cost

$1,200 – $4,000

Crew

2 people

Overview

A DC submersible pump driven straight off panels, lifting into an elevated or ground-level storage tank, with a pressure pump and bladder tank giving you normal taps and showers. Pumping to storage rather than to pressure is the key design decision: it lets the pump work when the sun works and lets you draw water at 3 a.m. This system also covers surface-pump variants for shallow wells and springs.

Key figures

Typical DC pump
24 – 48 V, 2 – 5 GPM
Max lift (helical rotor)
up to 750 ft
Array size
2 – 6 × 400 W panels
Head loss
0.43 psi per vertical foot
Pressure tank
20 – 40 gal bladder, 40/60 psi cut-in/out

Read before starting

  • 01DC at 48 V does not shock like mains but WILL arc and start fires. Fuse the array and use a DC-rated disconnect.
  • 02Never work in or over an open well casing without the cap secured and the hole covered. Falls into casings are fatal.
  • 03Dropping a pump requires safety rope rated well above the pump + pipe + water weight. Never lower by the power cable.
  • 04Well drilling, casing and sometimes pump installation are licensed activities in most jurisdictions. Check before you drill.
  • 05Test the bore water before you plumb it to a tap — arsenic, nitrate and coliform are invisible.

Procedure

0/9 complete
  1. Test the bore before you buy anything

    Record static water level, drawdown under pumping, and recovery rate in gallons per minute. Send a sample for a full potability panel. A pump that outpaces recovery will pull the bore dry, burn out and possibly silt up the screen — this single number decides the pump you buy.

    Hazard · Never size the pump by household demand. Size it by bore recovery, then buy storage to cover demand.

  2. Calculate total dynamic head

    Total head = vertical lift from pumping water level to tank inlet, plus friction loss in the pipe run, plus any discharge pressure. Add friction from the manufacturer's chart (typically 2 – 5 ft per 100 ft at these flow rates). Choose the pump from its head/flow curve at your target GPM — never from its headline maximum.

    Field tip · Add 15% headroom to your calculated head. Pipes scale, water levels drop in drought, and an undersized pump is a very expensive lesson.

  3. Size and mount the array

    Pump wattage divided by expected peak-sun hours gives your daily volume. Mount the array on a fixed ground rack tilted at latitude, facing true south (north in the southern hemisphere), with zero shading between 9 a.m. and 3 p.m. Keep the array within the controller's MPPT voltage window at both cold-morning open-circuit voltage and hot-afternoon operating voltage.

    Hazard · Cold mornings raise panel Voc. Check the low-temperature Voc figure against the controller's maximum input, or you will destroy the controller on the first frost.

  4. Assemble the drop pipe

    Lay out the pipe on clean ground. Attach the pump, torque arrestor and safety rope. Tape the cable to the rising main every 10 ft with UV tape — snug, never tight enough to pinch. Fit the check valve above the pump per the manufacturer's spacing.

  5. Lower the pump

    Two people minimum, using the gin pole and pulley. Lower steadily on the safety rope, never the cable or the pipe alone. Set the pump at least 10 ft above the bore floor and at least 20 ft below the pumping water level. Terminate at a pitless adapter or well seal, then fit the sanitary cap.

    Hazard · Once the pump is past the casing lip, one person keeps hands on the rope at all times. A dropped pump means a fishing job or a new bore.

  6. Trench and wire

    Trench below frost line (24 – 36 in typical) from the bore to the tank and from the array to the controller. Run the water line and the cable in the same trench with warning tape 6 in above. Terminate all splices in adhesive heatshrink and a rated junction box. Install the DC disconnect within sight of the controller.

  7. Fit protection switches

    Wire the tank float switch to the controller's remote-off input so the pump stops when storage is full, and the bore low-water probe to shut down before the pump can suck air. These two switches are the difference between a pump that lasts a decade and one that lasts a summer.

  8. Build the pressure side

    From the tank outlet: gate valve, 20 µm sediment prefilter, pressure pump, check valve, bladder tank, then house. Pre-charge the bladder tank to 2 psi below the pump's cut-in pressure with a bicycle pump and a tyre gauge, tank empty. Wrong pre-charge is the single most common cause of the pump cycling on and off every few seconds.

    Field tip · Fit unions either side of the pump. When it eventually fails you will swap it in fifteen minutes instead of cutting pipe.

  9. Disinfect and commission

    Shock-chlorinate the bore and the plumbing per local guidance, run every tap until you smell chlorine, leave 12 hours, then flush to waste until clear. Retest for coliform before drinking. Log flow rate and daily volume in your maintenance record as the baseline you will compare against later.

Maintenance schedule

MonthlyRead pressure gauge cycle; wash the array face if dusty
QuarterlyChange or clean the sediment prefilter
AnnuallyCheck bladder tank pre-charge; inspect all DC terminations for corrosion
AnnuallyFull water potability test — coliform, nitrate, pH, hardness
Every 5 yearsPull the pump for inspection; check safety rope and cable insulation

Fault finding

Pressure pump cycles rapidly (2 – 3 s on/off)

Likely causeBladder tank has lost pre-charge or the bladder has ruptured

CorrectionIsolate, drain, check air pressure at the schrader valve. If water sprays out, the bladder has failed — replace the tank.

Pump runs but no water at midday

Likely causeBore drawn down below pump intake

CorrectionReduce flow rate with a flow restrictor and let the bore recover. Consider a smaller pump or larger storage.

Poor output on clear days

Likely causeShading, dirty panels, or controller dropping out of MPPT

CorrectionCheck array voltage at the controller under load. Even one shaded cell in a string can halve output.

Water is cloudy after pumping restarts

Likely causeSediment disturbance or a failing well screen

CorrectionRun to waste for 10 minutes. If it persists, the bore may need redevelopment by a driller.